Classes, Rules, Monitors and Discoveries for OpsLogix VMware Management Pack. This guide is written for the 1.3.1652.0 version of the management pack.
Monitors
Cluster Overall Status
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.Cluster | OpsLogix.IMP.VMWare.Monitoring.MonitorType.3Stage.Object.PropertyValue |
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.Datastore | OpsLogix.IMP.VMWare.Monitoring.MonitorType.3Stage.DataStore.FreeSpaceGBvPct.HighIsHealthy |
Info
| Enabled | Target | TypeId |
|---|---|---|
| false | olxVMware!OpsLogix.IMP.VMWare.Datastore | OpsLogix.IMP.VMWare.Monitoring.MonitorType.3Stage.DataStore.Usage.HighIsHealthy |
Datastore Overall Status
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.Datastore | OpsLogix.IMP.VMWare.Monitoring.MonitorType.3Stage.Object.PropertyValue |
Distributed Virtual Switch Overall Status
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.DistributedVirtualSwitch | OpsLogix.IMP.VMWare.Monitoring.MonitorType.3Stage.Object.PropertyValue |
ESX Host Config Status
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.MonitorType.3Stage.Object.PropertyValue |
ESX Connection Config Status
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.MonitorType.3Stage.Object.PropertyValue |
Info
| Enabled | Target | TypeId |
|---|---|---|
| false | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.MonitorType.3Stage.Perf.Host.LowIsHealthy |
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.MonitorType.3Stage.Perf.Host.LowIsHealthy |
Info
| Enabled | Target | TypeId |
|---|---|---|
| false | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.MonitorType.3Stage.Perf.Host.LowIsHealthy |
ESX Host DataStoreMount Status
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.MonitorType.3Stage.Object.PropertyValue |
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.MonitorType.3Stage.Perf.Host.LowIsHealthy |
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.MonitorType.3Stage.Perf.Host.LowIsHealthy |
Info
| Enabled | Target | TypeId |
|---|---|---|
| false | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.MonitorType.3Stage.Perf.Host.LowIsHealthy |
ESX Host Overall Status
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.MonitorType.3Stage.Object.PropertyValue |
ESX Host Power Status
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.MonitorType.3Stage.Object.PropertyValue |
ESX Host Service Run Status
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.HostService | OpsLogix.IMP.VMWare.Monitoring.MonitorType.3Stage.Object.PropertyValue |
Network Overall Status
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.Network | OpsLogix.IMP.VMWare.Monitoring.MonitorType.3Stage.Object.PropertyValue |
ResourcePool Overall Status
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ResourcePool | OpsLogix.IMP.VMWare.Monitoring.MonitorType.3Stage.Object.PropertyValue |
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.MonitorType.3Stage.Perf.VM.LowIsHealthy |
Info
| Enabled | Target | TypeId |
|---|---|---|
| false | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.MonitorType.3Stage.Perf.VM.LowIsHealthy |
Info
| Enabled | Target | TypeId |
|---|---|---|
| false | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.MonitorType.3Stage.Perf.VM.LowIsHealthy |
Info
| Enabled | Target | TypeId |
|---|---|---|
| false | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.MonitorType.3Stage.Perf.VM.LowIsHealthy |
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.MonitorType.3Stage.Perf.VM.LowIsHealthy |
Info
| Enabled | Target | TypeId |
|---|---|---|
| false | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.MonitorType.3Stage.Perf.VM.LowIsHealthy |
Virtual Machine Overall Status
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.MonitorType.3Stage.Object.PropertyValue |
Virtual Machine Active SnapShot Count
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.MonitorType.3Stage.Object.PropertyValueByDouble.LowIsHealthy |
Virtual Machine Power Status
Info
| Enabled | Target | TypeId |
|---|---|---|
| false | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.MonitorType.3Stage.Object.PropertyValue |
Virtual Machine VMware Tools Status
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.MonitorType.3Stage.Object.PropertyValue |
Virtual Machine VMware Tools Version Check
Info
| Enabled | Target | TypeId |
|---|---|---|
| false | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.MonitorType.3Stage.Object.PropertyValue |
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.VirtualMachineSnapshot | OpsLogix.IMP.VMWare.Monitoring.MonitorType.3Stage.Object.PropertyValueByDouble.LowIsHealthy |
Rules
Configured size of the datastore in kiloBytes.
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.Datastore | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.Datastore.Optimized |
Amount of machine memory used on the host. Consumed memory includes Includes memory used by the Service Console, the VMkernel, vSphere services, plus the total consumed metrics for all running virtual machines.
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.Host.Optimized |
The memory used by the VMkernel to maintain and execute the VM.
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.Host.Optimized |
Sum of swapin metrics from all powered-on virtual machines on the host.
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.Host.Optimized |
Sum of swapout metrics from all powered-on virtual machines on the host.
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.Host.Optimized |
Memory usage as percentage of total configured or available memory. Percentage of available machine memory: consumed machine-memory-size
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.Host.Optimized |
Amount of guest physical memory that is currently reclaimed from the virtual machine through ballooning. This is the amount of guest physical memory that has been allocated and pinned by the balloon driver. The sum of all vmmemctl values for all powered-on virtual machines, plus vSphere services on the host. If the balloon target value is greater than the balloon value, the VMkernel inflates the balloon, causing more virtual machine memory to be reclaimed. If the balloon target value is less than the balloon value, the VMkernel deflates the balloon, which allows the virtual machine to consume additional memory if needed.
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.Host.Optimized |
Sum of all granted metrics for all powered-on virtual machines, plus machine memory for vSphere services on the host.
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.Host.Optimized |
Sum of all active metrics for all powered-on virtual machines plus vSphere services (such as COS, vpxa) on the host.
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.Host.Optimized |
The average amount of shared memory. Shared memory represents the entire pool of memory from which sharing savings are possible. The amount of memory that this has been condensed to is reported in shared common memory. So, total saving due to memory sharing equals shared memory minus shared common memory.
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.Host.Optimized |
Sum of zero metrics for all powered-on virtual machines, plus vSphere services on the host.
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.Host.Optimized |
Amount of memory that is unreserved. Memory reservation not used by the Service Console, VMkernel, vSphere services and other powered on VMs user-specified memory reservations and overhead memory. This statistic is no longer relevant to virtual machine admission control, as reservations are now handled through resource pools.
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.Host.Optimized |
The amount of swap memory currently in use. A large amount of swap memory is not a performance problem. This could be memory that the guest doesn't need. Check the swap rates (swapin, swapout) to see if the guest is actively in need of more memory than is available.
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.Host.Optimized |
Amount of memory that is unreserved by swap
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.Host.Optimized |
Amount of machine memory that is shared by all powered-on virtual machines and vSphere services on the host. Subtract this metric from the shared metric to gauge how much machine memory is saved due to sharing: shared - sharedcommon = machine memory (host memory) savings (KB)
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.Host.Optimized |
VMkernel virtual address space dedicated to VMkernel main heap and related data. For informational purposes only: not useful for performance monitoring.
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.Host.Optimized |
Refers to VMkernel swapping. Sum of swapin values for all powered-on virtual machines on the host.
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.Host.Optimized |
Amount of memory swapped-out to disk. Sum of swapout metrics from all powered-on virtual machines on the host.
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.Host.Optimized |
Amount of machine memory used by VMkernel for core functionality, such as device drivers and other internal uses. Does not include memory used by virtual machines or vSphere services.
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.Host.Optimized |
Total amount of memory reservation used by powered-on virtual machines and vSphere services on the host. Includes overhead amount.
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.Host.Optimized |
Ready time is the time spend waiting for CPU(s) to become available in the past update interval.
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.Host.Optimized |
The CPU utilization. The maximum possible value here is the frequency of the processors times the number of cores. As an example^ a VM using 4000 MHz on a system with four 2 GHz processors is using 50% of the CPU (4000 / (4 * 2000) = 0.5)
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.Host.Optimized |
The CPU utilization. This value is reported with 100% representing all processor cores on the system. As an example^ a 2-way VM using 50% of a four-core system is completely using two cores.
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.Host.Optimized |
CPU Reserved Capacity
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.Host.Optimized |
CPU Idle
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.Host.Optimized |
Swap wait time is time that the world spent waiting for memory to be swapped in. When the VM is waiting for memory^ it is not doing work.
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.Host.Optimized |
Wait time is the time spent waiting for hardware or VMkernel lock thread locks during the last update interval.
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.Host.Optimized |
CPU Used
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.Host.Optimized |
CPU Usage (None)
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.Host.Optimized |
CPU Usage (Minimum)
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.Host.Optimized |
CPU Usage (Maximum)
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.Host.Optimized |
CPU Usage in MHz (None)
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.Host.Optimized |
CPU Usage in MHz (Minimum)
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.Host.Optimized |
CPU Usage in MHz (Maximum)
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.Host.Optimized |
Network utilization (combined transmit- and receive-rates) during the interval.
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.Host.Optimized |
Aggregated disk I/O rate. For hosts, this metric includes the rates for all virtual machines running on the host during the collection interval.
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.Host.Optimized |
Highest latency value across all datastores used by the host.
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.Host.Optimized |
DataStore Storage I/O Control aggregated IOPS (Average)
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.Host.Optimized |
Percentage of time Storage I/O Control actively controlled datastore latency in percent (Average)
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.Host.Optimized |
DataStore Storage I/O Control normalized latency (Average)
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.Host.Optimized |
DataStore Storage I/O Control datastore maximum queue depth (Latest)
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.ESXHost | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.Host.Optimized |
Ready time is the time spend waiting for CPU(s) to become available in the past update interval.
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.VM.Minimized.Optimized |
The CPU utilization. The maximum possible value here is the frequency of the processors times the number of cores. As an example^ a VM using 4000 MHz on a system with four 2 GHz processors is using 50% of the CPU (4000 / (4 * 2000) = 0.5)
Info
| Enabled | Target | TypeId |
|---|---|---|
| false | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.VM.Optimized |
The CPU utilization. This value is reported with 100% representing all processor cores on the system. As an example^ a 2-way VM using 50% of a four-core system is completely using two cores.
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.VM.Minimized.Optimized |
The CPU Total CPU time spent in wait state in millisecond
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.VM.Minimized.Optimized |
CPU Idle
Info
| Enabled | Target | TypeId |
|---|---|---|
| false | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.VM.Optimized |
CPU Used
Info
| Enabled | Target | TypeId |
|---|---|---|
| false | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.VM.Optimized |
Guaranteed time is reported as the amount of the reservation time that the VM used in the past update interval. As an example^ if 2000 MHz have been reserved for the VM on an four-way^ 2 GHz host^ that's 25% of the CPU resource. In a 20s update interval^ there are 80^000 ms available on this four-way system. That means 20^000 ms of time has been reserved. If a VM used only half of its available cycles^ the guaranteed time is 10^000 ms.
Info
| Enabled | Target | TypeId |
|---|---|---|
| false | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.VM.Optimized |
CPU Usage (None)
Info
| Enabled | Target | TypeId |
|---|---|---|
| false | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.VM.Optimized |
CPU Usage (Minimum)
Info
| Enabled | Target | TypeId |
|---|---|---|
| false | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.VM.Optimized |
CPU Usage (Maximum)
Info
| Enabled | Target | TypeId |
|---|---|---|
| false | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.VM.Optimized |
CPU Usage in MHz (None)
Info
| Enabled | Target | TypeId |
|---|---|---|
| false | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.VM.Optimized |
CPU Usage in MHz (Minimum)
Info
| Enabled | Target | TypeId |
|---|---|---|
| false | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.VM.Optimized |
CPU Usage in MHz (Maximum)
Info
| Enabled | Target | TypeId |
|---|---|---|
| false | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.VM.Optimized |
The amount of machine memory that is in use by the VM. While a VM may have been configured to use 4 GB of RAM, as an example, it might have only touched half of that. Of the 2 GB left, half of that might be saved from memory sharing. That would result in 1 GB of consumed memory.
Info
| Enabled | Target | TypeId |
|---|---|---|
| false | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.VM.Optimized |
Total of all overhead metrics for powered-on virtual machines, plus the overhead of running vSphere services on the host
Info
| Enabled | Target | TypeId |
|---|---|---|
| false | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.VM.Optimized |
Rate at which memory is swapped from disk into active memory during the interval. This counter applies to virtual machines and is generally more useful than the swapin counter to determine if the virtual machine is running slow due to swapping, especially when looking at real-time statistics.
Info
| Enabled | Target | TypeId |
|---|---|---|
| false | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.VM.Optimized |
Rate at which memory is being swapped from active memory to disk during the current interval. This counter applies to virtual machines and is generally more useful than the swapout counter to determine if the virtual machine is running slow due to swapping, especially when looking at real-time statistics.
Info
| Enabled | Target | TypeId |
|---|---|---|
| false | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.VM.Optimized |
Memory usage as percentage of total configured or available memory. Percentage of configured virtual machine "physical" memory: active virtual machine configured size
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.VM.Minimized.Optimized |
Amount of guest physical memory that is currently reclaimed from the virtual machine through ballooning. This is the amount of guest physical memory that has been allocated and pinned by the balloon driver. The sum of all vmmemctl values for all powered-on virtual machines, plus vSphere services on the host. If the balloon target value is greater than the balloon value, the VMkernel inflates the balloon, causing more virtual machine memory to be reclaimed. If the balloon target value is less than the balloon value, the VMkernel deflates the balloon, which allows the virtual machine to consume additional memory if needed.
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.VM.Minimized.Optimized |
Guest "physical" memory that is mapped to machine memory. Includes shared memory amount. Does not include overhead.
Info
| Enabled | Target | TypeId |
|---|---|---|
| false | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.VM.Optimized |
The amount of memory used by the VM in the past small window of time. This is the "true" number of how much memory the VM currently has need of. Additional, unused memory may be swapped out or ballooned with no impact to the guest's performance.
Info
| Enabled | Target | TypeId |
|---|---|---|
| false | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.VM.Optimized |
Amount of guest "physical" memory shared with other virtual machines (through the VMkernels transparent page-sharing mechanism, a RAM de-duplication technique). Includes amount of zero memory area.
Info
| Enabled | Target | TypeId |
|---|---|---|
| false | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.VM.Optimized |
The amount of zero pages in the guest. Zero pages are not represented in machine memory so this results in 100% savings when mapping from the guest to the machine memory.
Info
| Enabled | Target | TypeId |
|---|---|---|
| false | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.VM.Optimized |
Amount of machine memory that is shared by all powered-on virtual machines and vSphere services on the host. Subtract this metric from the shared metric to gauge how much machine memory is saved due to sharing: shared - sharedcommon = machine memory (host memory) savings (KB)
Info
| Enabled | Target | TypeId |
|---|---|---|
| false | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.VM.Optimized |
Free address space in the VMkernels main heap. Varies based on number of physical devices and configuration options. There is no direct way for the user to increase or decrease this statistic. For informational purposes only: not useful for performance monitoring.
Info
| Enabled | Target | TypeId |
|---|---|---|
| false | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.VM.Optimized |
Amount of free machine memory on the host. VMkernel has four free-memory thresholds that affect memory reclamation:
Info
| Enabled | Target | TypeId |
|---|---|---|
| false | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.VM.Optimized |
Current amount of guest physical memory swapped out to the virtual machine's swap file by the VMkernel. Swapped memory stays on disk until the virtual machine needs it. This statistic refers to VMkernel swapping and not to guest OS swapping. swapped = swapin + swapout
Info
| Enabled | Target | TypeId |
|---|---|---|
| false | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.VM.Optimized |
Amount of memory available for swapping. Target size for virtual machine swap file, as calculatd by the VMkernel. The VMkernel uses values for this metric with the swap metric to stop and start swapping, as follows: -If swaptarget greater than swapped, the VMkernel can start swapping when necessary.-If swaptarget less than swapped, the VMkernel stops swapping memory. Since swapped memory stays swapped until the virtual machine accesses it, swapped memory can be greater than the memory swap target, possibly for a prolonged period of time. This simply means that the swapped memory is not currently needed by the virtual machine and is not a cause for concern.
Info
| Enabled | Target | TypeId |
|---|---|---|
| false | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.VM.Optimized |
Refers to VMkernel swapping. Amount swapped-in to memory from disk. Total amount of data that has been read into machine memory from the swap file since the virtual machine was powered on.
Info
| Enabled | Target | TypeId |
|---|---|---|
| false | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.VM.Optimized |
Amount of memory swapped-out to disk. Total amount of data that the VMkernel has written to the virtual machines swap file from machine memory. This statistic refers to VMkernel swapping and not to guest OS swapping.
Info
| Enabled | Target | TypeId |
|---|---|---|
| false | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.VM.Optimized |
Target value set by VMkernal for the virtual machines memory balloon size. In conjunction with vmmemctl metric, this metric is used by VMkernel to inflate and deflate the balloon for a virtual machine, as follows: - If vmmemctltarget greater than vmmemctl, VMkernel can inflate the balloon and make machine memory currently consumed by the virtual machine available to other virtual machines on the host. (Size of vmmemctl increases as balloon inflates.) -If vmmemctltarget less than vmmemctl, VMkernel deflates balloon so that virtual machine can consume more memory, when needed. (Size of vmmemctl decreases as balloon deflates.)
Info
| Enabled | Target | TypeId |
|---|---|---|
| false | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.VM.Optimized |
Network utilization (combined transmit- and receive-rates) during the interval. Sum of data transmitted and received across all virtual NIC instances connected to the virtual machine
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.VM.Minimized.Optimized |
Aggregated disk I/O rate.
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.VirtualMachine | OpsLogix.IMP.VMWare.Monitoring.DataSource.Perf.VM.Minimized.Optimized |
Check every interval if there are new alerts triggerd in VCenter. So so then create a SCOM alert of it.
Info
| Enabled | Target | TypeId |
|---|---|---|
| true | olxVMware!OpsLogix.IMP.VMWare.vCenter | olxVMware!OpsLogix.IMP.VMWare.Assembly.Object.Alarm.Monitor.DS |